Welcome to Shenzhen Chengchi Circuit Technology Co., Ltd official website

CN Shenzhen Chengchi Circuit Technology Co., Ltd.
Service Hotline

+8618129931046 Mr. Liao

Shenzhen Chengchi Circuit Technology Co., Ltd.
EN
Shenzhen Chengchi Circuit Technology Co., Ltd. Shenzhen Chengchi Circuit Technology Co., Ltd.

domestic pcb manufacturer

Home >  domestic pcb manufacturer > 

PCB Boards for Ultrasound Diagnostic Equipment

Time:2025-12-20 Views:1

  PCB boards for ultrasound diagnostic equipment are high-performance circuit boards that power and control ultrasound machines—devices that use high-frequency sound waves (2-18MHz) to generate images of internal body structures (e.g., fetus, organs, blood vessels). These PCBs are among the most complex medical PCBs, requiring ultra-high-speed signal processing, precise analog-to-digital conversion (ADC), and high-voltage pulse generation—all while complying with IEC 60601-1 (medical safety) and FDA regulations for diagnostic accuracy. Unlike other medical PCBs, ultrasound PCBs must handle both low-voltage digital signals (for image processing) and high-voltage analog signals (for ultrasound transducer excitation), making signal isolation and noise reduction critical.

  Core design characteristics of ultrasound diagnostic equipment PCBs include:

  High-Voltage Pulse Generation for Transducers: Ultrasound transducers (the probe that emits and receives sound waves) require high-voltage pulses (50-200V) to generate ultrasound waves. PCBs include high-voltage pulse generators (using components like MOSFETs or IGBTs) that produce precise, short-duration pulses (10-100ns) with adjustable amplitude—critical for controlling image resolution (higher voltage for deeper tissue penetration, lower voltage for superficial structures). These circuits are isolated from low-voltage components using high-voltage opto-isolators and reinforced insulation to prevent voltage breakdown and ensure patient safety. For example, a cardiac ultrasound PCB generates 150V pulses to penetrate the chest wall, with feedback circuits to adjust pulse width based on tissue depth.

  Ultra-High-Speed Signal Processing and ADC: When ultrasound waves reflect off body tissues, the transducer converts them into weak analog signals (microvolt range) that must be processed in real time. PCBs integrate high-speed ADCs (12-16 bit resolution, sampling rates up to 100MSPS) to convert analog signals to digital data, and field-programmable gate arrays (FPGAs) or digital signal processors (DSPs) to process the data—filtering noise, calculating tissue depth, and constructing 2D/3D images. For 4D ultrasound (real-time 3D), PCBs use multi-core DSPs (e.g., Texas Instruments TMS320C6678) to handle data rates exceeding 1GB/s, ensuring smooth image rendering.

  Signal Isolation and Noise Reduction: Ultrasound signals are extremely sensitive to noise—even small EMI can distort images. PCBs use strict signal isolation: separate analog, digital, and high-voltage ground planes; shielded high-voltage traces; and low-noise power supplies (LDO regulators with <10μV noise). They also include EMI filters on input/output ports to block external interference (e.g., from hospital power lines) and internal noise (from FPGAs/DSPs). For example, a fetal ultrasound PCB isolates the transducer’s analog signal path from the digital image processing circuit using galvanic isolation, ensuring no digital noise corrupts the weak reflected signals.

  Thermal Management for High-Power Components: High-voltage pulse generators and FPGAs generate significant heat—PCBs use thermal management techniques like thick copper traces (2-4oz) for heat dissipation, thermal vias (connecting top and bottom layers to spread heat), and heat sinks for high-power components. Some PCBs use metal-core PCBs (MCPCBs) with aluminum substrates to enhance thermal conductivity, preventing overheating during long scanning sessions (e.g., 30-minute abdominal ultrasounds). Thermal sensors monitor component temperature, triggering fans or reducing power if temperatures exceed safe limits (typically 85°C).

  Compliance and accuracy are paramount: ultrasound PCBs must meet IEC 60601-1’s leakage current limits (<50μA) and FDA’s performance standards (e.g., image resolution, depth accuracy) to ensure diagnostic reliability. They undergo rigorous testing—electrical safety tests, thermal cycling, and image quality validation using phantom models (simulated body tissues). By combining high performance, safety, and precision, ultrasound diagnostic equipment PCBs enable non-invasive, accurate imaging for a wide range of medical applications—from prenatal care to cardiac monitoring.